显示标签为“Huawei MA5600T”的博文。显示所有博文
显示标签为“Huawei MA5600T”的博文。显示所有博文

2014年6月18日星期三

How to choose the N66 cabinet for Huawei MA5600

As we show you that the three types of N66 cabinet, you must be confused with how to choose the N66 cabinet for Huawei MA5600 series, below are the details for the configuration of N66 cabinet, you can according to your need of shelves to choose the cabinet.Works for the Huawei MA5600T and Huawei MA5603T.

Table 1 Specifications of the Huawei GPON N66-22 cabinet (1 SCU + 14 ADEFs + fan tray)
Configuration
Maximum Number of Subscribers
1 service shelf + 1 SPL shelf
896
2 service shelves + 2 SPL shelves
1792
3 service shelves
2688

Figure 1 Configuration of the N66-22 cabinet




















Table 2 Specifications of the H66-18 cabinet
Configuration
Maximum Number of Subscribers
1 service shelf + 1 SPL shelf
896
2 service shelves
1792

Figure 2 Configuration of the H66-18 cabinet




 Table 3 Specifications of the N66E-18 cabinet
Configuration
Maximum Number of Subscribers
1 service shelf
896
1 service shelf + 1 SPL shelf
896
2 service shelves
1792
  
Figure 3 Configuration of the N66E-18 cabinet


More related:
The three types of N66 cabinet for Huawei MA5600
The Function of MA5600 Boards
How to Collect Traffic and Rate Statistics an ONT on the MA5600T/MA5603T

2014年6月13日星期五

How to Troubleshoot the Fault That the NMS Displays that the EMAC Chip of the MA5600T Board Is Faulty



If the NMS displays that the EMAC chip of the Huawei MA5600T board is faulty, is the board hardware or the chip faulty? How to troubleshoot such a fault?

Answer
If the MA5600T reports that the EMAC chip is faulty, it does not indicate that the board hardware or chip is faulty.

Reset the board or remove and insert the board. If the fault is rectified, there is no need to replace the board. If the fault persists, replace the board.

More related:
The Function of MA5600 Boards
The Feature of Huawei MA5600
GPON – Gigabit Passive Optical Network

 

 

 

 

2014年6月10日星期二

How to Collect Traffic and Rate Statistics an ONT on the MA5600T/MA5603T



Question
On the MA5600T/MA5603T of different commercial versions, how to collect traffic and rate statistics of an ONT?

Answer
The following table lists the statistics collection modes and query commands supported by different commercial versions of the MA5600T/MA5603T.

Statistics Collection Mode
Query Command
Version
Packets count of a VLAN
display statistics vlan vlanid [ label innervlanid] V800R005C33B
V800R005C33B
118
V800R006C02S
PC100
V800R007C00
V800R007C01
V800R008C01
V800R008C02
V800R008C03
Volume of traffic streams
display statistics service-port index
V800R005C33B
118
V800R006C02S
PC100
V800R007C00
V800R007C01
V800R008C01
V800R008C02
V800R008C03
Huawei GPON traffic
display ont traffic portid ontid [ ontportid ]
V800R006C02S
PC100
V800R007C00
V800R007C01
V800R008C01
V800R008C02
V800R008C03
Packets count of an ONT
display statistics ont portid ontid
V800R006C02S
PC100
V800R007C00
V800R007C01
Traffic and packets count of an ONT
display statistics ont frameid/slotid portid ont-id
V800R008C01
V800R008C02
V800R008C03
Traffic of a PON port
display port traffic portid
V800R007C00
V800R007C01
V800R008C01
V800R008C02
V800R008C03