Question
How to load the version of the standby control board of the MA5600 if the
active control board functions properly?
Answer
If one of the control boards of the MA5600 is faulty, the faulty control
board needs to be
replaced. In replacement, the following scenarios may occur:
l For
H801SCUN, there is no need to check the versions of control boards on the live
network or the version of the substitute control board. This is because the
H801SCUN supports duplicating of all information to the standby control board.
No manual operation is required.
l For
H801SCUB, H801SCUF, or H801SCUL,
– When the version of the original
control board is earlier than V800R008C01, automatic
information duplication to the standby control board is supported if the
version of the
substitute control board is V800R006C02 or later. No manual operation is
required.
– When the version of the original
control board is V800R008C01 or later, automatic
information duplication to the standby control board is supported if the
version of the
substitute control board is V800R008C01 or later. No manual operation is
required.
– When the version of the original
control board is V800R008C01 or later, a patch is
required for the substitute control board to support automatic information
duplication
to the standby control board if the version of the substitute control
board is earlier than
– V800R006C02: SPC124 or a later patch
– V800R007C00: SPC307 or a later patch
– V800R007C01: SPC307 or a later patch
– When the version of the substitute
control board is earlier than V800R006C02.
automatic information duplication to the standby control board is not
supported.
Therefore, manually upgrade the substitute control board to the version of
the control
board on the live network for information synchronization.